Aspire-1000-2

Operating Parameters of Aspire-1000-2


Sr. No. Machine Description Specifications
1 Mould on straight arm 1000 Ltr... x 2. 500 Ltr... x 4 750 Ltr... x 2 300 Ltr... x 4
2 Total Cycle Time 65 min. for Double Layer
3 Production Per Day 40,000 Ltr.... Max (24 hrs).
4 Production Capacity 40 tanks/day for 1000 Ltr... & 750 Ltr..
80 tanks/day for 500 Ltr... & 300 Ltr..
5 Electrical Load 8 Hp (415 Volt 3 phase).
6 Diesel Consumption
***LPG Consumption
***Biomass Consumption
4.5 Ltr... / Cycle
3.8 Kg / Cycle
12 kg / Cycle
7 Process Temperature 180- 220 Degree.
8 Space for Machine L 7 Mtr x W 5 Mtr x H 5 Mtr.
9 Machine suitable for DL, TL FL or Foam layer
10 Manpower 2 Semi skilled persons per shift.

***Machine supplied with Diesel burner other burners are optional


Technical Specifications of Aspire-1000-2


Machine Description Specifications
Spindles 1
Maximum Weight on Straight Arm 300 Kg
Spider Diameter Spider Diameter
Max Mould Diameter 1150 mm
Max Mould Height 1250 mm
Major Axis R.P.M 0-6
Minor Axis R.P. 0-6
Max Temperature ˚C 250.0
Circulating Blower C.F 18000
Electrical Supply Voltage 415 V, 50 Hz 3 Phase & Neutral
Blower Motor 5 HP 415 V 1440 RPM Crompton
Major Motor 2 HP 415V 1440 RPM Crompton
Minor Motor 1 HP 415V 1440 RPM Crompton
Burner Motor
Riello
0.25 230 Volt 1440 RPM make
Major Gear Box Size 40 Ratio 70:1 Make Panchal
Minor Gear box Size 30 Ratio 40:1 Make Panchal
Bearings All ZKL Make
Blower Impeller 450 mm Double blades
Major Shaft OD 150 mm ID 60 m
Minor shaft OD 50 mm Solid
Furnace Inside sheet 0.40 mm SS polish sheet
Furnace Outside sheet 1.2 mm CRC Sheet
Insulation Mineral wool
Spider for 1000 / 750 Ltr... mould 1250 mm
Spider for 500/ 300 Ltr... Mould 880 mm

SCOPE OF OUR SUPPLY


Scope of supply includes machine and control panel as specified above. Customer will have to provide for Foundation and civil work as required. Electrical connection up to panel. 2T Electric hoist for Loading / Unloading of mould and product. Diesel Storage tank is your scope. Machine is supplied with Diesel burner. Biomass burner is optional or in your scope. We recommend 2,00,000 Kcal Biomass burner for PS 1000/2 and 3,00,000 Kcal Biomass burner for higher models. Installation of Biomass burner is also not in our scope.


ERECTION AND COMMISSIONING


Erection and commissioning are free of cost you will arrange to and fro, lodging and food for our team. You will also arrange necessary unskilled person, Crane or Chain pulley block, necessary tools, Raw material and fuel for trail. Our team will train your operator for Process, Trouble shooting and Maintenance of Machines. Our team will stay at your place for Max 5 days.